Every effort has been made to ensure the accuracy of all information contained herein. e-nitiative shall not be liable for any changes resulting in wrong product description, tax code and/or price. The shown information (specifications, prices, taxes) should be considered as an indication and can be changed at any moment and without any prior notice.
RS-DATA bvba
Onze lieve vrouw ten steenstraat 1
B-3300 Tienen
Belgium
Telephone : 016/820712
VAT : BE 466.551.192
APC NetShelter Rack PDU Advanced, Switched, 34.6kW, 3PH, 415V, 60A, 560P6, 42 Outlet
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.
Switched
Single-phase
0U
Vertical
Black
LCD
N
48 AC outlet(s)
IEC 60309
C13 coupler, C15 coupler, C19 coupler, C21 coupler
Y
CSA C22.2 No 62368-1, FCC part 15 subpart B, UL 62368-1
200 - 240 V
50/60 Hz
60 A
240 V
240 V
34600 VA
60 A
48 A
56 mm
75 mm
1826 mm
12.4 kg
15.4 kg
262 mm
132 mm
1980 mm
-5 - 60 °C
-25 - 65 °C
5 - 95%
5 - 95%
0 - 3048 m
0 - 15240 m